Model No.
|
S-240-12
|
OUTPUT
|
DC VOLTAGE
|
12V
|
RATED CURRENT
|
20A
|
CURRENT RANGE
|
0~20A
|
RATED POWER
|
250W
|
RIPPLE & NOISE(max).
|
150mVp-p
|
VOLTAGE ADJ.RANGE
|
8-12V
|
VOLTAGE TOLERANCE
|
±1.0%
|
LINE REGULATION
|
±0.5%
|
LOAD REGULATION
|
±0.5%
|
SETUP,RISE TIME
|
1000ms, 50ms/230VAC 1000ms,50ms/115VAC at full load
|
HOLD UP TIME(Typ.)
|
20ms/230VAC 16ms/115VAC at full load
|
INPUT
|
VOLTAGE RANGE
|
90 ~ 132VAC / 180 ~ 264VAC by switch 254 ~ 370VDC
|
FREQUENCY RANGE
|
47~63HZ
|
EFFICIENCY(Typ.)
|
87%
|
AC CURRENT(Typ.)
|
4.5A/115VAC 2.5A/230VAC
|
INRUSH CURRENT(Typ.)
|
40A/115VAC 55A/230VAC
|
LEAKAGE CURENT
|
<3.5mA / 240VAC
|
PROTECTION
|
OVERLOAD
|
105 ~ 150% rated output power
|
Protection type : Constant current limiting, recovers automatically after fault condition is removed
|
OVER VOLTAGE
|
27.6 ~ 32.4V
|
Protection type :Shut down O/P voltage, re-power on to recover
|
OVER TEMPERATURE
|
95°C+5°C (3.3V); 100°C+5°C(5V); 90°C+5°C (7.5V); 85°C+5°C(12~24V); 80°C+5°C(27~36V); 75°C+5°C(48V) (TSW1) Detect on case
|
Protection type : Shut down O/P voltage, recovers automatically after temperature goes down
|
ENVIRONMENT
|
WORKING TEMP.
|
-20~+50°C (Refer to "Derating Curve")
|
WORKING HUMIDITY
|
20~90% RH non-condensing
|
STORAGE TEMP HUMIDITY
|
-20~+85°C, 10~95%RH
|
TEMPCOEFFICIENT
|
±0.03% /°C(0~50°C )
|
VIBRATION
|
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
|
SAFETY & EMC
|
SAFETY STANDARDS
|
U60950-1 approved
|
WITHSTAND VOLTAGE
|
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
|
ISOLATIONRESISTANCE
|
I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC / 25°C/ 70% RH
|
OTHERS
|
MTBF
|
271.9Khrs min MIL-HDBK-217F(25°C)
|
DIMENSION
|
200*110*50mm (L*W*H)
|
PACKING
|
0.63Kg
|